Abstract :Passive cooling system is used to improve the thermal performance of a house. The thermal performance of a passive cooling house with double skins is an object of this measurement. We measured the temperature distribution around the double skin walls and heat flow rate to clarify the thermal characteristics of the house. Moreover, ventilation rate without openings was measured by C0_2 concentration method to get the air tightness of the house. Then, we made a simulation program for the prediction of air temperature based on the stable heat transmission to compare with the measured data.